Votronic VAC 1215 Station Automatic Charger with 4m Oil Flex CableVotronic VAC 1215 Station Automatic Charger with 5m Spiral Cable
Availability:
Available in 3-5 working days
Only small number of pieces available
Availability:
Available in 3-5 working days
Product details
Automatic voltage disconnection | Fully automatic continuous operation |
Battery regeneration | Parallel and buffer operation |
Product description
The charger series VAC-Station is intended for use in vehicle sheds and fulfills all specifications of the FNFW in the current fire department standard DIN 14679 for external charging and subsequent trickle charging of starter and auxiliary batteries in fire fighting vehicles with the exception of the resistance against splash water IP21.
Details
VAC 1215 station with 4m oil flex cable version:
Mains cable, oil flex cable, operating instructions
VAC 1215 station nit 5m spiral cable version
Mains cable, spiral cable, operating instructions
Details
- Charging programs no. 5, 6, 7, 8, 9 and 10 adjustable for all battery types
- Automatic, fast and at the same time gentle full charging and charge maintenance of the vehicle battery according to DIN 14679
- Trouble-free operation and co-supply of devices connected to the vehicle electrical system (e.g. charging trays)
- Charging plug is automatically disconnected if battery is missing (against short circuits and plug corrosion)
- Optical and acoustic warning in case of battery and operating faults
- Outstanding charging technology
- Fully automatic continuous operation for constant readiness for use of the batteries
- Compensation of voltage losses on the charging cables for exact compliance with the charging voltages
- Variable installation position
- Electronics protected against moisture
- Charging voltages are free of peaks and regulated to prevent overcharging
- Automatic battery regeneration during long idle periods (twice a week)
- VAC 1215 station with 5m spiral cable version has more details:
- - Provided for direct connection of the charging plug at the end of the cable
- - Cable length approx. 1.2m, extendable to approx. 5m
- - oil and acid resistant cable suitable for high mechanical stress and use in damp rooms
- VAC 1215 station with 4m oil-flex cable are optional for further cable extension:
- - Automatic cable reel 5m (max. 16A charging current) or
- - Spiral charging cable 5m complete with charging plug or
- - Spiral charging cable 5m with C-plug or charging plug
- - Recommended accessories: connection box
- 5 "MOTOR": Charging program for lead-acid/wet batteries, characteristic IU1oU2oU3: characteristic similar to alternator/generator for moving (mobile) use (acid stratification) with particularly low maintenance (battery gassing, water consumption). Charging and charge maintenance of starter batteries in emergency vehicles, according to a conventional proposal of the Fire Service Standards Committee (FNFW). For conventional standard starter batteries, starter batteries "Absolutely maintenance-free", "Maintenance-free according to EN", "Maintenance-free according to DIN", "Maintenance-free", "Low maintenance".
- 6 "L": Closed acid/wet batteries with water consumption: L = low according to DIN EN 50342-1, characteristic curve IU1oU2oU4. Characteristic with medium U1 level for acid batteries in vehicle-mounted or external chargers with a fixed location.
- 7 "VL": Closed acid/wet batteries with water consumption: VL = very low according to DIN EN 50342-1, characteristic IU1oU2oU3. Characteristic curve with high U1 level for acid batteries in vehicle built-in or external chargers with fixed location.
- 8 "Non-woven": Sealed batteries (VRLA) with AGM/non-woven technology: characteristic IU1oU2oU3. Characteristic for AGM batteries in vehicle-mounted or external chargers with fixed location.
- 9 "Gel": Sealed batteries (VRLA) with gel technology: characteristic IU1oU2oU3. Characteristic curve for gel batteries in vehicle-mounted or external chargers with a fixed location.
- 10 "External": without battery type assignment: characteristic IU1oU2oU3: charging of the vehicle battery by external charger via vehicle plug in vehicle bays with assigned or free parking spaces. Universal program for charging and charge maintenance of acid/gel/AGM batteries.
- BR: Automatic battery regeneration
- FB: Remote control/display connection
- Electronics moisture-proof
- Rated voltage (AC) in [V]: 230
- Operating voltage range (AC) in [V]: 190 - 265 (full charging power)
- Power consumption (AC) in max. [W]: 270
- Sinusoidal power factor correction (CosPhi = 1): yes
- Nominal battery voltage (DC) in [V]: 12
- Secondary charge output "S" in [A] -
- Charging characteristic: IU1oU2
- Voltage limitation for all charge modes/programs [V]: 15
- Voltage ripple in [mV]: rms < 40
- Number of charge outputs: 1
- Device mounting position: any
- Temperature range [°C]: -20 to +45
- Degree/class of protection: I / IP 21
- Dimensions (W x H x D) incl. mounting flanges, without connections in [mm]: 210 x 71 x 160
- Ambient conditions, humidity: max. 95% room humidity, non-condensing
VAC 1215 station with 4m oil flex cable version:
Mains cable, oil flex cable, operating instructions
VAC 1215 station nit 5m spiral cable version
Mains cable, spiral cable, operating instructions
Features
Type battery | Charger |
Weight | 1250 g |
Battery capacity | 60 - 160 Ah |
Charging current | 15 A |
Voltage | 12 V |
Design | VAC 1215 with 4m oil flex cable |
ean | 4250683615732 |
Manufacturer Article No. | 0538 |
Features
Type battery | Charger |
Weight | 1250 g |
Battery capacity | 60 - 160 Ah |
Charging current | 15 A |
Voltage | 12 V |
Design | VAC 1215 with 5m spiral cable |
Dimensions (LxWxH) | x x 0 cm |
ean | 4250683615725 |
Manufacturer Article No. | 0528 |
Legal information
General Safety Information
Manufacturer information
Votronic
Johann-Friedrich-Diehm-Str. 10
36341 Lauterbach
Germany
verkauf@votronic.de
Legal information
General Safety Information
Manufacturer information
Votronic
Johann-Friedrich-Diehm-Str. 10
36341 Lauterbach
Germany
verkauf@votronic.de