Macht euch bereit für ein neues Camping-Jahr!

  Camping Specialist Since 1958
  Free shipping from 50 €
Service
EN | DE
Language:
Deutsch
English
Nederlands
Österreich
Français
Italiano
Español
Shipping Country:
Germany
Denmark
Ireland
Sweden
Finland
Norway
Slovenia
Hungary
Poland
Lithuania
Netherlands
Austria
Spain
Italy
France
Slovakia
Bulgaria
Belgium
Luxembourg
Romania
Estonia
Czech Republic
Portugal
Latvia
Greece
Croatia
Malta
Switzerland
Liechtenstein
Tents Tents
All products in "Tents"
Outdoor & Leisure Outdoor & Leisure
All products in "Outdoor & Leisure"
Furniture Furniture
All products in "Furniture"
Household Household
All products in "Household"
Water & Sanitation Water & Sanitation
All products in "Water & Sanitation"
Electronics Electronics
All products in "Electronics"
Multimedia Multimedia
All products in "Multimedia"
Caravanning Caravanning
All products in "Caravanning"
Heating & Cooling Heating & Cooling
All products in "Heating & Cooling"
Clothing Clothing
All products in "Clothing"
Spare Parts Spare Parts
All products in "Spare Parts"
Trending Topics Trending Topics
All products in "Trending Topics"
New New
All products in "New"
Sale Sale
All products in "Sale"
Store Store
Change store
Address

To the store page
Language & Country
Language
Shipping country

Votronic VAC 1215 Station Automatic Charger with 4m Oil Flex CableVotronic VAC 1215 Station Automatic Charger with 5m Spiral Cable

RRP 480,40 €
259,- €
Prices incl. statutory VAT, free shipping
Item number: 237325
RRP 532,30 €
435,- €
Prices incl. statutory VAT, free shipping
Item number: 569671

 
Availability: Available in 3-5 working days
Only small number of pieces available
Availability: Available in 3-5 working days
 Added
 Added

Product details

Automatic voltage disconnection Fully automatic continuous operation
Battery regeneration Parallel and buffer operation

Product description

The charger series VAC-Station is intended for use in vehicle sheds and fulfills all specifications of the FNFW in the current fire department standard DIN 14679 for external charging and subsequent trickle charging of starter and auxiliary batteries in fire fighting vehicles with the exception of the resistance against splash water IP21.

Details
  • Charging programs no. 5, 6, 7, 8, 9 and 10 adjustable for all battery types
  • Automatic, fast and at the same time gentle full charging and charge maintenance of the vehicle battery according to DIN 14679
  • Trouble-free operation and co-supply of devices connected to the vehicle electrical system (e.g. charging trays)
  • Charging plug is automatically disconnected if battery is missing (against short circuits and plug corrosion)
  • Optical and acoustic warning in case of battery and operating faults
  • Outstanding charging technology
  • Fully automatic continuous operation for constant readiness for use of the batteries
  • Compensation of voltage losses on the charging cables for exact compliance with the charging voltages
  • Variable installation position
  • Electronics protected against moisture
  • Charging voltages are free of peaks and regulated to prevent overcharging
  • Automatic battery regeneration during long idle periods (twice a week)
  • VAC 1215 station with 5m spiral cable version has more details:
  • - Provided for direct connection of the charging plug at the end of the cable
  • - Cable length approx. 1.2m, extendable to approx. 5m
  • - oil and acid resistant cable suitable for high mechanical stress and use in damp rooms
  • VAC 1215 station with 4m oil-flex cable are optional for further cable extension:
  • - Automatic cable reel 5m (max. 16A charging current) or
  • - Spiral charging cable 5m complete with charging plug or
  • - Spiral charging cable 5m with C-plug or charging plug
  • - Recommended accessories: connection box
Charging programs
  • 5 "MOTOR": Charging program for lead-acid/wet batteries, characteristic IU1oU2oU3: characteristic similar to alternator/generator for moving (mobile) use (acid stratification) with particularly low maintenance (battery gassing, water consumption). Charging and charge maintenance of starter batteries in emergency vehicles, according to a conventional proposal of the Fire Service Standards Committee (FNFW). For conventional standard starter batteries, starter batteries "Absolutely maintenance-free", "Maintenance-free according to EN", "Maintenance-free according to DIN", "Maintenance-free", "Low maintenance".
  • 6 "L": Closed acid/wet batteries with water consumption: L = low according to DIN EN 50342-1, characteristic curve IU1oU2oU4. Characteristic with medium U1 level for acid batteries in vehicle-mounted or external chargers with a fixed location.
  • 7 "VL": Closed acid/wet batteries with water consumption: VL = very low according to DIN EN 50342-1, characteristic IU1oU2oU3. Characteristic curve with high U1 level for acid batteries in vehicle built-in or external chargers with fixed location.
  • 8 "Non-woven": Sealed batteries (VRLA) with AGM/non-woven technology: characteristic IU1oU2oU3. Characteristic for AGM batteries in vehicle-mounted or external chargers with fixed location.
  • 9 "Gel": Sealed batteries (VRLA) with gel technology: characteristic IU1oU2oU3. Characteristic curve for gel batteries in vehicle-mounted or external chargers with a fixed location.
  • 10 "External": without battery type assignment: characteristic IU1oU2oU3: charging of the vehicle battery by external charger via vehicle plug in vehicle bays with assigned or free parking spaces. Universal program for charging and charge maintenance of acid/gel/AGM batteries.
Technical features
  • BR: Automatic battery regeneration
  • FB: Remote control/display connection
  • Electronics moisture-proof
Technical data
  • Rated voltage (AC) in [V]: 230
  • Operating voltage range (AC) in [V]: 190 - 265 (full charging power)
  • Power consumption (AC) in max. [W]: 270
  • Sinusoidal power factor correction (CosPhi = 1): yes
  • Nominal battery voltage (DC) in [V]: 12
  • Secondary charge output "S" in [A] -
  • Charging characteristic: IU1oU2
  • Voltage limitation for all charge modes/programs [V]: 15
  • Voltage ripple in [mV]: rms < 40
  • Number of charge outputs: 1
  • Device mounting position: any
  • Temperature range [°C]: -20 to +45
  • Degree/class of protection: I / IP 21
  • Dimensions (W x H x D) incl. mounting flanges, without connections in [mm]: 210 x 71 x 160
  • Ambient conditions, humidity: max. 95% room humidity, non-condensing
Scope of delivery
VAC 1215 station with 4m oil flex cable version:
Mains cable, oil flex cable, operating instructions
VAC 1215 station nit 5m spiral cable version
Mains cable, spiral cable, operating instructions

Features

Type battery Charger
Weight 1250 g
Battery capacity 60 - 160 Ah
Charging current 15 A
Voltage 12 V
Design VAC 1215 with 4m oil flex cable
ean 4250683615732
Manufacturer Article No. 0538

Features

Type battery Charger
Weight 1250 g
Battery capacity 60 - 160 Ah
Charging current 15 A
Voltage 12 V
Design VAC 1215 with 5m spiral cable
Dimensions (LxWxH) x x 0 cm
ean 4250683615725
Manufacturer Article No. 0528

Legal information

General Safety Information

  • Nur mit geeigneten Batterien betreiben
  • Knopfzelle nicht verschlucken – kann zu schweren Gesundheitsrisiken führen
  • Nur Batterien der angegebenen Größe verwenden

Manufacturer information

Votronic

Johann-Friedrich-Diehm-Str. 10

36341 Lauterbach

Germany

verkauf@votronic.de

Legal information

General Safety Information

  • Nur mit geeigneten Batterien betreiben
  • Knopfzelle nicht verschlucken – kann zu schweren Gesundheitsrisiken führen
  • Nur Batterien der angegebenen Größe verwenden