Availability:
Available in 3-5 working days
Product details
Precise | Practical |
Product description
The US-16 changeover station enables you to supply 230 V AC loads without interference via two different voltage sources, for example via an inverter and the public 230 V mains supply. The maximum connected load is 3600 VA.
With the priority circuit you determine which voltage source is to be used preferentially - if this voltage source fails, the changeover station automatically switches to the substitute voltage source. In this way, your devices continue to run despite a power failure or exhausted battery.
The high-quality relays ensure a precise switching threshold. Thus, your inverter is particularly well protected against backfeeding of external voltage.
Recommended use: Suitable for solar island systems, motor vehicles, service and commercial vehicles, motor homes, caravans, motor and sail boats and many more.
Details
Mains priority circuit:
The 230 V AC grid is connected to the AC2 input
(higher priority).
The inverter is connected to the input AC2
(higher priority) is connected.
Switching station US-16 PE Connection terminal Operating instructions DE, GB, FR, NL
With the priority circuit you determine which voltage source is to be used preferentially - if this voltage source fails, the changeover station automatically switches to the substitute voltage source. In this way, your devices continue to run despite a power failure or exhausted battery.
The high-quality relays ensure a precise switching threshold. Thus, your inverter is particularly well protected against backfeeding of external voltage.
Recommended use: Suitable for solar island systems, motor vehicles, service and commercial vehicles, motor homes, caravans, motor and sail boats and many more.
Details
- Suitable for sine wave inverters up to max. 3600 VA
- Microprocessor controlled priority circuit
- Freely selectable mains priority circuit
- Reliably switches between two 230 V AC power sources
- Precise switching thanks to high quality relays
- Protected against overload and short circuit
- Dust and water jet protected housing (IP 55)
- Input voltage 230 V AC, 50 Hz
- Input current (max.) 16 A
- Output voltage 230 V AC, 50 Hz
- Power (max.) 3600 VA
- Switching time 0.5 seconds
- Fuse T 16 A / 250 V
- Protection overload, short circuit
- Housing plastic
- Protection class IP 55
- Inputs Screw terminals, connection terminal
Mains priority circuit:
The 230 V AC grid is connected to the AC2 input
(higher priority).
- I.e. the battery is protected and the inverter is protected against external voltage at the same time.
- Only when AC2 is de-energized, input AC1 switches on the power supply via battery and inverter.
The inverter is connected to the input AC2
(higher priority) is connected.
- I.e. the current is primarily taken from the battery via the inverter (e.g. when using solar island systems).
- Only when the inverter switches off due to deep discharge protection, the 230 V AC mains is connected via input AC1.
Switching station US-16 PE Connection terminal Operating instructions DE, GB, FR, NL
Features
Design | US-16 |
Weight | 0,4 kg |
Output voltage | 230 V |
Input voltage | 230 V |
Dimensions (LxWxH) | 155 x 140 x 75 mm |
ean | 4030072400039 |
Manufacturer Article No. | 400034 |