Votronic VAC 2416 Station Automatic Charger with 5m Spiral CableVotronic VAC 2416 Station Automatic Charger with 4m Oil Flex Cable
Availability:
Sold out
Availability:
Sold out
Product details
6 loading programs adjustable | Automatic battery regeneration |
Automatic release of the charging plug | Delivery without charging plug |
Product description
Fully automatic chargers according to DIN 14679 for fire engines and emergency vehicles for direct charging current supply at the vehicle.
Details
VAC 2416 station with 4m oil flex cable version:
Mains cable, oil flex cable, operating instructions
VAC 2416 station with 5m spiral cable version:
Mains cable, spiral cable, operating instructions
Details
- Charging programs no. 5, 6, 7, 8, 9 and 10 adjustable for all battery types
- Automatic, fast and gentle full charging and charge maintenance of the vehicle battery according to DIN 14679
- Trouble-free operation and co-supply of devices connected to the vehicle electrical system (e.g. charging trays)
- Charging plug is automatically disconnected if battery is missing (against short circuits and plug corrosion)
- Optical and acoustic warning in case of battery and operating faults
- Outstanding charging technology
- Fully automatic continuous operation for constant readiness for use of the batteries
- Compensation of voltage losses on the charging cables for exact compliance with the charging voltages
- Variable installation position
- Electronics protected against moisture
- Charging voltages are free of peaks and regulated to prevent overcharging
- Automatic battery regeneration during long idle periods (twice a week)
- VAC 2416 station with 4m oil-flex cable version for further cable extension optionally provided:
- - Automatic cable retractor 5m (max. 16A charging current) or
- - Spiral charging cable 5m complete with charging plug or
- - Spiral charging cable 5m Art. 2318 with C-plug charging plug
- - Recommended accessories: Connection box
- VAC 2416 station with 5m spiral cable version has further details:
- - oreseen for direct connection of the charging plug at the end of the cable (e.g. charging plug 12V/24V or C-plug)
- - Cable length approx. 1,2m, extendable to approx. 5m
- - oil and acid resistant cable suitable for high mechanical stress and use in damp rooms
- 5 "MOTOR": Charging program for lead-acid/wet batteries, characteristic IU1oU2oU3: characteristic similar to alternator/generator for moving (mobile) use (acid stratification) with particularly low maintenance (battery gassing, water consumption). Charging and charge maintenance of starter batteries in emergency vehicles, according to a conventional proposal of the Fire Service Standards Committee (FNFW). For conventional standard starter batteries, starter batteries "Absolutely maintenance-free", "Maintenance-free according to EN", "Maintenance-free according to DIN", "Maintenance-free", "Low maintenance".
- 6 "L": Closed acid/wet batteries with water consumption: L = low according to DIN EN 50342-1, characteristic curve IU1oU2oU4. Characteristic with medium U1 level for acid batteries in vehicle-mounted or external chargers with a fixed location.
- 7 "VL": Closed acid/wet batteries with water consumption: VL = very low according to DIN EN 50342-1, characteristic IU1oU2oU3. Characteristic curve with high U1 level for acid batteries in vehicle built-in or external chargers with fixed location.
- 8 "Non-woven": Sealed batteries (VRLA) with AGM/non-woven technology: characteristic IU1oU2oU3. Characteristic for AGM batteries in vehicle-mounted or external chargers with fixed location.
- 9 "Gel": Sealed batteries (VRLA) with gel technology: characteristic IU1oU2oU3. Characteristic curve for gel batteries in vehicle-mounted or external chargers with a fixed location.
- 10 "External": Without assignment of battery type: Characteristic IU1oU2oU3. Charging of the vehicle battery by external charger via vehicle plug in vehicle bays with assigned or free parking spaces. Universal program for charging and charge maintenance of acid/gel/AGM batteries.
- BR: Automatic battery regeneration
- FB: Remote control/display connection
- Electronics moisture-proof
- Charging power in [V]/[A]: 24 / 16
- Rated voltage (AC) in [V]: 230
- Operating voltage range (AC) in [V]: 190 - 265 (full charging power)
- Power consumption (AC) in max. [W]: 530
- Sinusoidal power factor correction (CosPhi = 1): yes
- Nominal battery voltage (DC) in [V]: 24
- Battery capacity in [Ah]: 70 - 160
- Charging current in [A]: 16
- Secondary charge output "S" in [A] -
- Charging characteristic: IU1oU2
- Voltage limitation for all charge modes/programs [V]: 30
- Voltage ripple in [mV]: rms < 50
- Number of charge outputs: 1
- Device mounting position: any
- Temperature range [°C]: -20 to +45
- Degree/class of protection: I / IP 21
- Dimensions (W x H x D) incl. mounting flanges, without connections in [mm]: 210 x 71 x 160
- Ambient conditions, humidity: max. 95% room humidity, non-condensing
VAC 2416 station with 4m oil flex cable version:
Mains cable, oil flex cable, operating instructions
VAC 2416 station with 5m spiral cable version:
Mains cable, spiral cable, operating instructions
Features
Type battery | Charger |
Weight | 1400 g |
Design | VAC 2416 with 5m spiral cable |
ean | 4250683615589 |
Manufacturer Article No. | 0544 |
Features
Type battery | Charger |
Weight | 1400 g |
Design | VAC 2416 with 4m oil flex cable |
ean | 4250683615749 |
Manufacturer Article No. | 0548 |
Legal information
Herstellerinformationen
Votronic
Johann-Friedrich-Diehm-Str. 10
36341 Lauterbach
Germany
verkauf@votronic.de
Legal information
Herstellerinformationen
Votronic
Johann-Friedrich-Diehm-Str. 10
36341 Lauterbach
Germany
verkauf@votronic.de